Lecture - B3 Review Questions
LHAP 302A-61-40680 (FA25) - Water and Light/Module B - Lighting/Lecture - B3 Review Questions.md
Download File
This resource is available as an original file download.
Extracted Text
Extracted from the original source file.
**Question 1**
Low voltage systems usually do not require permits or inspection.
* True
* False
**Question 2**
The cable for the low voltage installation will need to be protected in a conduit.
* True
* False
**Question 3**
Wire connectors must be CSA approved, for outdoor use.
* True
* False
**Question 4**
The transformer should be located central to the lighting fixtures so that the wire runs extend out from it like the spokes of a wheel.
* True
* False
**Question 5**
A 30-45 cm coil of wire should be left at the transformer and a loop above ground at the location of each fixture.
* True
* False
**Question 6**
The transformer does not need be connected to a receptacle that is protected by a GFI.
* True
* False
**Question 7**
When testing the system, if any of the fixtures do not light up, immediately rewire that fixture.
* True
* False
1. **True**
2. **False**
3. **True**
4. **True**
5. **True**
6. **False**
7. **False**